The following is a list of new or recently discovered limitations known to exist in ANSYS Fluent 18.2. Where possible, suggested workarounds are provided.
Models
For all multiphase models, the solve/set/expert
option for not freeing temporary solver memory is incompatible with dynamic
adaption, not only in parallel, but now in serial as well. ()
The Use DPM Domain option of the hybrid parallel DPM tracking method cannot be used with the following:
PDF Transport model
Eulerian Wall Film model
Cases that include a wall / shadow pair
If a user is not part of a video group, a session on a local Linux machine with SLES11, SP4, and OpenGL may terminate abnormally during an injection setup for the discrete phase model case. To avoid this issue, it is recommended that the user restarts the ANSYS Fluent session with the driver option -x11 or that the user is added to the video group on that machine. Work-around: Deactivate the injection visualization during the case setup by using the following text command:
(rpsetvar 'dpm/visualize-injections? #f)
Graphics, Reporting, and Postprocessing
When running the parallel version of ANSYS Fluent, the Curve Length function for solution XY plotting is only supported when the curvilinear surface is contained within a single partition.
Scene animations created using Key Frames in the Animate dialog box are not compatible with graphics object displays on iso-surfaces.
File/Data Import and Export
If you are accessing a file using a Universal Naming Convention (UNC) path, you must ensure that you have permission to access to all of the folders in the path or you will not be able to open the file.
It is no longer possible to export volume data for RadTherm software from the serial version of ANSYS Fluent. ()
To properly view Fieldview Unstructured (.fvuns)
results from a serial ANSYS Fluent simulation (as well as parallel), mesh files
must be exported using the fieldview-unstruct-grid
text command.
User-Defined Functions (UDFs)
For serial UDFs, note the following:
The DEFINE_RW_FILE macro is no longer
supported for serial UDFs in the following circumstances: in a
compiled UDF on Windows 2012 or earlier; in an interpreted UDF on
any platform. As a workaround for such unsupported combinations, you
can parallelize the UDF (as described in Parallelizing Your Serial UDF in the Fluent Customization Manual).
The macro PRINCIPAL_FACE_P can only be
used in compiled UDFs, not only in parallel, but now in serial as
well.
Interpreted UDFs cannot be used with an Infiniband interconnect not only when running in parallel, but now in serial as well. The compiled UDF approach must be used instead.
For the discrete phase model, the Shared Memory parallel processing method is no longer compatible with serial UDFs when running in serial; note that no action is required for cases created in previous releases, as the Shared Memory selection is automatically changed to Hybrid in version 18.2.
Note that new macro types that become available in version 19.0 and later are not guaranteed to be supported if they are not parallelized (see Parallelizing Your Serial UDF in the Fluent Customization Manual).
Serial Processing
If the network connection is lost during a serial (as well as a parallel) calculation, the ANSYS Fluent session may terminate abnormally.
ANSYS Fluent uses several TCP/IP ports for communications and error handling. Port conflicts with other programs trying to use the same ports are handled by ANSYS Fluent and generate warnings similar to the following:
428: mpt_accept: warning: incorrect exercise message "GET /" from 10.1.0.188 on port 56564
Long running large sessions are more prone to generating such warnings, but these are generally safe for you to ignore.
For a list of ongoing Fluent limitations listed in previous ANSYS, Inc. Release Notes, refer to Known Limitations in ANSYS Fluent 18.2 in the Fluent Getting Started Guide.