Interpolated data post-processing algorithms are the last step in the data transfer process. In many situations (such as an implicit coupling where the number of coupling iterations within a coupling step is more than one), the interpolated target data needs to be post-processed before it is exposed to the target participant of the data transfer. Two optional post-processing algorithms may be applied to the target data generated during interpolation: ramping and under-relaxation. Each of these algorithms is used to improve convergence of the overall analysis. Other post-processing algorithms that are automatically applied involve:
creation of supplemental data on mesh. For information on the creation of supplemental data, see Data Pre-Processing Algorithms.
Unless otherwise noted, post-processing algorithms are applied to each:
data transfer location (node), and
component of vector data transfers
The ramping controlled by the System Coupling service works
by slowing the application of the source-side value on the target-side
of the data transfer. For each data transfer location (node) where is true, the
following formula is applied:
(12) |
where
|
| |
|
| |
|
| |
|
| |
|
|
Under-relaxation works by limiting a potentially large variation of the target-side data between two successive coupling iterations. For each data transfer location (node), the following formula is applied:
(13) |
where
|
| |
|
| |
|
| |
|
ω is the under-relaxation factor (URF). In a transient analysis, in the first coupling iteration of every coupling step, the URF is overridden and set to 1, and so data transferred at this coupling iteration is not under-relaxed. |
The default for the initial value used as the reference target-side
value () in Equation 12 and Equation 13 is based on the physical type of the variable. The default values
are listed in Table 3: Initial Values used for the Reference Target-Side Value.
Table 3: Initial Values used for the Reference Target-Side Value
|
Variable Type |
Initial Value used for the Reference Target-Side
Value ( |
Notes |
|---|---|---|
|
Incremental displacement |
0.0 [m] |
For the ramping algorithm, the reference target-side value for incremental displacement is always 0.0 [m] for every coupling step. |
|
Force |
0.0 [N] | |
|
Temperature |
295.15 [K] |
Variables of this type include temperature and near wall temperature. |
|
Heat Rate |
0.0 [W] | |
|
Heat Transfer Coefficient |
0.0 [Wm-2K-1] |
These defaults for the initial values above can be overridden using the methods discussed in the section Expert Settings. Note that for the ramping algorithm, the reference target-side value for displacement cannot be modified using expert settings.
Although uncommon, it is possible that unphysical values, such as negative heat transfer coefficients, are provided by the data transfer source or are generated during mapping. To ensure unphysical values are not applied to the data transfer target, these unphysical values are clipped to be within a valid range. For example, any negative heat transfer coefficient values are changed to 0 [Wm-2K-1] before being transferred to the target participant.
The variable(s) that are clipped and their valid range are listed in the table below. Note that at the end of any coupling step where clipping is used, the System Coupling Log file will have a message about the clipping.
|
Variable Type |
Minimum Value |
Maximum Value |
|---|---|---|
|
Heat Transfer Coefficient |
0 [Wm-2K-1] |
unlimited |