22.1.1. Hanging Node Adaption

Hanging node adaption is the default procedure used in ANSYS Fluent. Meshes produced by this method are characterized by nodes on edges and faces that are not vertices of all the cells sharing those edges or faces, as shown in Figure 22.1: Example of a Hanging Node.

Figure 22.1:  Example of a Hanging Node

Example of a Hanging Node

The hanging node adaption method uses a variety of predefined templates to recursively refine cells in the mesh. As implemented in ANSYS Fluent it can refine triangles, quadrilaterals, tetrahedra, hexahedra, wedges, and pyramids, but not polyhedra. It requires additional memory to maintain the hierarchy of mesh refinement levels, which is necessary for the mesh coarsening procedure that recovers the original mesh.

The cells marked for refinement are divided as described here:

Figure 22.2: Hanging Node Adaption of 2D Cell Types and Figure 22.3: Hanging Node Adaption of 3D Cell Types illustrate the division of the supported cell shapes.

To maintain accuracy, neighboring cells are not allowed to differ by more than one level of refinement. This prevents the adaption from producing excessive cell volume variations (reducing truncation error) and ensures that the positions of the parent (original) and child (refined) cell centroids are similar (reducing errors in the flux evaluations).

Figure 22.2:  Hanging Node Adaption of 2D Cell Types

Hanging Node Adaption of 2D Cell Types

Figure 22.3:  Hanging Node Adaption of 3D Cell Types

Hanging Node Adaption of 3D Cell Types

The mesh can be coarsened after it has been refined, by reintroducing inactive parent cells (uniting the child cells to reclaim the previously subdivided parent cell). An inactive parent cell is reactivated if all its children are marked for coarsening. You can eventually reclaim the original mesh with repeated application of the coarsening. Through this process, it is not possible to coarsen the mesh further than the original mesh.

The hanging node method has the following limitations: