For information about setting up the DO model, see the following sections:
For information about accelerating the DO solver, see Accelerating Discrete Ordinates (DO) Radiation Calculations.
When you select the Discrete Ordinates model, the Radiation Model dialog box will expand to show inputs for Angular Discretization (see Figure 12.11: The Radiation Model Dialog Box (DO Model)). In this section, you will set parameters for the angular discretization and pixelation described in Angular Discretization and Pixelation in the Theory Guide.
Theta Divisions () and Phi Divisions (
) will define the number of control angles used to discretize
each octant of the angular space (see Figure 5.3: Angular Coordinate System in the Theory Guide). Note that higher levels of
discretization are recommended for problems where specular exchange of radiation
is important to increase the likelihood of the correct beam direction being
captured. For a 2D model, ANSYS Fluent will solve only 4 octants (due to
symmetry); therefore, a total of
directions
will be solved. For a 3D model, 8 octants are solved,
resulting in
directions
. By default, the number of Theta
Divisions and the number of Phi Divisions
are both set to 2. For most practical problems, these settings are acceptable,
however, a setting of 2 is considered to be a coarse estimate. Increasing the
discretization of Theta Divisions and Phi
Divisions to a minimum of 3, or up to 5, will achieve more
reliable results. A finer angular discretization can be specified to better
resolve the influence of small geometric features or strong spatial variations
in temperature, but larger numbers of Theta Divisions and
Phi Divisions will add to the cost of the
computation.
Theta Pixels and Phi Pixels are used
to control the pixelation that accounts for any control volume overhang (see
Figure 5.7: Pixelation of Control Angle in the Theory Guide and the
figures and discussion preceding it). For problems involving gray-diffuse
radiation, the default pixelation of is usually sufficient. For problems involving symmetry,
periodic, specular, or semi-transparent boundaries, a pixelation of
is recommended and will achieve acceptable results. The
computational effort, as a result of increasing the pixelation, is less than the
computational effort caused by increasing the divisions. You should be aware,
however, that increasing the pixelation adds to the cost of computation.
Important: Note that pixelations are applied to boundary faces by default.
If you want to model non-gray radiation using the DO model, you can specify
the Number of Bands () under Non-Gray Model in the expanded
Radiation Model dialog box (Figure 12.19: The Radiation Model Dialog Box (Non-Gray DO Model)). For a 2D model, ANSYS Fluent will
solve
directions. For a 3D model,
directions will be solved. By default, the Number of
Bands is set to zero, indicating that only gray radiation will be
modeled. Because the cost of computation increases directly with the number of
bands, you should try to minimize the number of bands used. In many cases, the
absorption coefficient or the wall emissivity is effectively constant for the
wavelengths of importance in the temperature range of the problem. For such
cases, the gray DO model can be used with little loss of accuracy. For other
cases, non-gray behavior is important, but relatively few bands are necessary.
For typical glasses, for example, two or three bands will frequently
suffice.
When a nonzero Number of Bands is specified, the
Radiation Model dialog box will expand once again to
show the Wavelength Intervals (Figure 12.19: The Radiation Model Dialog Box (Non-Gray DO Model)). You can specify a
Name for each wavelength band, as well as the
Start and End wavelength of the
band in m. Note that the wavelength bands are specified for vacuum
(
). ANSYS Fluent will automatically account for the refractive
index in setting band limits for media with
different from unity.
The frequency of radiation remains constant as radiation travels across a
semi-transparent interface. The wavelength, however, changes such that
is constant. Therefore, when radiation passes from a medium
with refractive index
to one with refractive index
, the following relationship holds:
(12–8) |
Here and
are the wavelengths associated with the two media. It is
conventional to specify the wavelength rather than frequency.
ANSYS Fluent requires you to specify wavelength bands (in
m) for an equivalent medium with
.
For example, consider a typical glass with a step jump in the absorption
coefficient at a cut-off wavelength of . The absorption coefficient is
for
and
for
. The refractive index of the glass is
. Since
is constant across a semi-transparent interface, the
equivalent cut-off wavelength for a medium with
is
using Equation 12–8. You should choose two
bands in this case, with the limits 0 to
and
to 100. Here, the upper wavelength limit has been chosen to be
a large number, 100, in order to ensure that the entire spectrum is covered by
the bands. When multiple materials exist, you should convert all the cut-off
wavelengths to equivalent cut-off wavelengths for an
medium, and choose the band boundaries accordingly.
The bands can have different widths and need not be contiguous. You can ensure
that the entire spectrum is covered by your bands by choosing and
. Here
and
are the minimum and maximum wavelength bounds of your
wavelength bands, and
is the minimum expected temperature in the domain.
ANSYS Fluent allows you to use a user-defined function (UDF) to modify the
emissivity weighting factor (which otherwise defaults to the black body emission factor
obtained from a standard Planck distribution). The emissivity weighting factor
appears in the emission term of the radiative transfer equation for the non-gray
model, as shown in Equation 5–61 in the Theory Guide. For more information, see
DEFINE_EMISSIVITY_WEIGHTING_FACTOR in
the Fluent Customization Manual.
For applications involving optical thicknesses greater than 10, you can enable the DO/Energy Coupling option in the Radiation Model (Figure 12.20: The Radiation Model Dialog Box with DO/Energy Coupling Enabled) in order to couple the energy and intensity equations at each cell, solving them simultaneously. This approach accelerates the convergence of the finite volume scheme for radiative heat transfer and can be used with the gray or non-gray radiation model.