The steps for setting up the dual cell heat exchanger model is as follows:
Read the mesh file.
If the mesh file does not already contain overlapping heat exchanger cores for primary and auxiliary fluids, then you must create a duplicate of the zone that represents the core using the following text command:
mesh → modify-zones → copy-move-cell-zone
See Copying Cell Zones for details on copying meshes.
Make sure that the auxiliary fluid mesh is divided into separate zones, one for each pass.
Setting Up Domain → Zones → Separate → Cells...
See Separating Cell Zones for details on separating meshes.
Make sure that the inlet and outlet for the heat exchanger are two separate zones.
Enable the calculation of energy in the Energy dialog box.
Setup → Models → Energy
ON
Enable the Dual Cell Model in the Heat Exchanger Model dialog box and click (Figure 13.3: The Heat Exchanger Model Dialog Box).
Setup → Models → Heat Exchanger
Edit...
Specify the inputs to the dual cell heat exchanger model, using the Dual Cell Heat Exchanger dialog box (Figure 13.4: The Dual Cell Heat Exchanger Dialog Box).
Click to define the heat exchanger. The Set Dual Cell Heat Exchanger dialog box will appear (Figure 13.5: The Set Dual Cell Heat Exchanger Dialog Box), where you will define the heat exchanger parameters.
Enter the heat exchanger Name or keep the default name. The suffix -1 is incremented automatically on defining more than one heat exchanger.
In the Fluid Zones tab (Figure 13.5: The Set Dual Cell Heat Exchanger Dialog Box)
Specify the Number of Passes of your heat exchanger.
Select the appropriate Primary and Auxiliary Fluid Zone, representing the heat exchanger core.
Important: The selected zones must be overlapping in physical space.
Click the Heat Rejection tab (Figure 13.6: The Heat Rejection Tab).
If you select Fixed Heat Rejection, set the inputs for the following:
Heat Rejection Targeted which is the heat rejection desired from the heat exchanger.
Inlet Zone for Temperature Updates allows ANSYS Fluent to change the temperature of the specified inlet zone in order to match the targeted heat rejection.
Temperature Update Under-Relaxation is a factor that controls convergence.
Iteration Interval Between Temperature Updates is used to control divergence.
Select Fixed Inlet Temperature if the output desired is total heat rejection.
Click the Performance Data tab (Figure 13.7: The Performance Data Tab).
You must decide whether you will select Raw Data or NTU Data from the Options list. Using the Raw Data option
specifies that the effectiveness () is evaluated as the ratio
of the rate of heat transfer between the primary and auxiliary fluids
(which you define in a table format) to the maximum possible rate
of heat transfer (
) for the current flow regime (see Equation 6–7 in the Theory Guide). The calculated
efficiency is then used to calculate the NTU value using the crossflow
formula for each and every set of primary and auxiliary flow rates.
If the heat exchanger manufacturer used a similar approach in evaluating the NTU values, then there is no difference between the Raw Data and NTU Data options. However, if a different methodology was used by the manufacturer that accounts for some possible non-uniformity of the profile or for the partial mixing of the flow stream, then the NTU Data option is likely to be more accurate. Similarly, you may be able to assess more accurate NTU values for your case using tables from the relevant literature. This can even include some mixing of the oncoming flow stream, for situations where the primary flow can deviate from the direction normal to the heat exchanger tubes; this can happen in heat exchangers where the fins are either very spaced or absent. Therefore, the NTU Data option can be more accurate if the NTU values are gathered at non-ideal conditions that bear a close resemblance to your simulated scenario.
If you select the Raw Data option, then specify the following:
Heat Transfer Data... opens the Heat Transfer Data Table Dialog Box, where you will enter experimental data that defines how heat transfer values relate to the fluid flow rates (Figure 13.8: The Heat Transfer Data Table Dialog Box). See Specifying Heat Exchanger Performance Data more details.
Effectiveness-NTU Relation computes the NTU values from the heat transfer data. Choose cross-flow-unmixed, parallel-flow, or counter-flow, all of which are described in NTU Relations.
Auxiliary Fluid Temperature is the inlet reference temperature for the auxiliary fluid.
Primary Fluid Temperature is the inlet reference temperature for the primary fluid.
If you select the NTU Data option, click to access the NTU Table dialog box. Populate this table in the same manner as described previously for the Heat Transfer Data Table Dialog Box. More information is available in Specifying Heat Exchanger Performance Data.
Click the Frontal Area tab. You have the option to specify the Primary and Auxiliary Fluid Core Frontal Area directly, or compute the area from a surface zone, as shown in Figure 13.9: The Frontal Area Tab.
Click the Coupling tab if you want to couple the heat exchanger passes (Figure 13.10: The Coupling Tab).
Consider the following example illustrating the coupling of a four-pass heat exchanger.
Figure 13.11: An Example of a Four-Pass Heat Exchanger shows a four-pass heat exchanger with air as the primary fluid and the coolant as the auxiliary fluid. The coolant flows through the tubes in a serpentine manner and air flows normal to the tubes, forming a cross flow pattern. To model this type of flow using the dual cell heat exchanger model, you must first generate the mesh. The mesh should contain the following:
A single primary cell zone.
Four adjacent auxiliary cell zones, one for each pass. Each auxiliary zone should be separated from the other by a coupled or uncoupled wall. Each pass will have its own inlet and outlet zones.
The primary and four auxiliary zones should overlap in physical space.
In the Coupling tab, mass-weighted-average is selected by default for the Temperature of the outlet of Pass 1 to the inlet of Pass 2. Similarly, the mass-weighted-average temperature of the outlet of Pass 2 will be applied at the inlet zone of Pass 3, and so on. Alternatively, you can couple the passes by using Profiles... in the Boundary Conditions task page or by using user-defined functions to define the Temperature in the Thermal tab of the relevant boundary condition dialog boxes. If you do so, make sure you select none from the Temperature drop-down list in the Coupling tab of the Set Dual Heat Exchanger dialog box.
Important: Make sure to specify the auxiliary zones in the correct order (that is the zone for Pass 1 should be selected first, then Pass 2, and so on) in the Fluid Zones tab of the Set Dual Cell Heat Exchanger dialog box.
Click to save the heat exchanger inputs.
To view the plot of NTU vs. primary mass flow rate for each auxiliary mass flow rate, click .
The button will plot the performance data curve for the selected heat exchanger. The performance data is supplied through the Performance Data tab.
When you close the Set Dual Cell Heat Exchanger dialog box, you will return to the Dual Cell Heat Exchanger dialog box, where you should now see the heat exchanger name in the Heat Exchanger list.
You can
Modify the settings of heat exchanger by selecting it from the list and clicking .
Copy the data of one heat exchanger to another using the button, assuming you have more than one heat exchanger.
Delete any unwanted heat exchangers by selecting the heat exchanger from the list and clicking .
Important: All the inputs are copied except for the name, primary fluid zone and auxiliary fluid zone.