/COM,ANSYS MEDIA REL. 182 (07/10/2017) REF. VERIF. MANUAL: REL. 182 /VERIFY,VM118 /PREP7 /TITLE, VM118, CENTERLINE TEMP. OF A HEAT GENERATING WIRE C*** HEAT, MASS AND MOMENTUM TRANS., ROHSENOW AND CHOI, 2ND. PR., PAGE 106, C*** EX. 6.5, USING PLANE55 ELEMENTS (PLANE ELEMENTS) ANTYPE,STATIC ! THERMAL ANALYSIS ET,1,PLANE55 MP,KXX,1,13 CSYS,1 ! CYLINDRICAL COORDINATE SYSTEM N,1,1E-10,-5 ! USE NON-ZERO RADIUS SINCE NODE IS NOT AT THETA=0 N,6,(.375/12),-5 FILL NGEN,2,10,1,6,1,,10 E,1,2,12,12 E,2,3,13,12 EGEN,4,1,2 CP,1,TEMP,2,12 ! COUPLING TO ENSURE CIRCUMFERENTIAL SYMMETRY CPSGEN,5,1,1 NSEL,S,LOC,X,(0.375/12) SF,ALL,CONV,5,70 NSEL,ALL BFE,ALL,HGEN,,111311.7 ! ELEMENT HEAT GENERATION OUTPR,BASIC,1 FINISH /SOLU SOLVE FINISH /POST1 *GET,TEMP,NODE,6,TEMP ! GET TEMPERATURE AT SURFACE NODE PI=2*ASIN(1) AREA=36*2*(0.375/12)*SIN(PI/36) ! COMPUTE AREA OF OUTER BOUNDARY HRATE=AREA*5.0*(TEMP-70) ! TOTAL HEAT DISSIPATION RATE PRNSOL,TEMP ! PRINT NODAL TEMPERATURES *status,parm ! SHOW STATUS *GET,TCL,NODE,1,TEMP *DIM,LABEL,CHAR,3,2 *DIM,VALUE,,3,3 LABEL(1,1) = 'T CL, ','T S, ','q, BTU' LABEL(1,2) = 'DEGREE F','DEGREE F','/hr ' *VFILL,VALUE(1,1),DATA,419.9,417.9,341.5 *VFILL,VALUE(1,2),DATA,TCL,TEMP,HRATE *VFILL,VALUE(1,3),DATA,ABS(TCL/419.9) ,ABS( TEMP/417.9 ),ABS(HRATE/341.5) SAVE,TABLE1 FINISH /PREP7 C*** USING SOLID70 ELEMENTS (SOLID ELEMENTS) EDELE,ALL ! DELETE PLANE55 ELEMENTS ET,1,SOLID70 ! CHANGE ELEMENT TYPE NGEN,2,20,1,16,1,,,-1 ! GENERATE 2ND PLANE OF NODES NUMCMP,ELEM E,1,2,12,12,21,22,32,32 E,2,3,13,12,22,23,33,32 EGEN,4,1,2 CPDELE,1,6,1 ! REMOVE PREVIOUS COUPLING SPECIFICATIONS CP,1,TEMP,1,21 ! COUPLING TO ENSURE AXIAL SYMMETRY CP,2,TEMP,2,12,22,32 ! COUPLING TO ENSURE CIRCUMFERENTIAL SYMMETRY CPSGEN,5,1,2 CSYS,1 NSEL,S,LOC,X,(0.375/12) SF,ALL,CONV,5,70 NSEL,ALL BFE,ALL,HGEN,1,111311.7 ! ELEMENT HEAT GENERATION FINISH /SOLU SOLVE FINISH /POST1 *GET,TEMP,NODE,6,TEMP ! GET TEMPERATURE AT SURFACE NODE PI=2*ASIN(1) AREA=36*2*(0.375/12)*SIN(PI/36) ! LENGTH ALONG 10 DEG ON OUTER FACE HRATE=AREA*5.0*(TEMP-70) ! TOTAL HEAT DISSIPATION RATE PRNSOL,TEMP ! PRINT NODAL TEMPERATURES *status,parm ! SHOW PARAMETER STATUS *GET,TCL,NODE,1,TEMP LABEL(1,1) = 'T CL, ','T S, ','q, BTU' LABEL(1,2) = 'DEGREE F','DEGREE F','/hr ' *VFILL,VALUE(1,1),DATA,419.9,417.9,341.5 *VFILL,VALUE(1,2),DATA,TCL,TEMP,HRATE *VFILL,VALUE(1,3),DATA,ABS(TCL/419.9) ,ABS( TEMP/417.9 ), ABS(HRATE/341.5) SAVE,TABLE2 RESUME,TABLE1 /COM /OUT,vm118,vrt /COM,------------------- VM118 RESULTS COMPARISON ------------- /COM, /COM, | TARGET | Mechanical APDL | RATIO /COM, /COM,STIF55 RESULTS: /COM, *VWRITE,LABEL(1,1),LABEL(1,2),VALUE(1,1),VALUE(1,2),VALUE(1,3) (1X,A8,A8,' ',F10.1,' ',F12.1,' ',1F15.3) /NOPR RESUME,TABLE2 /GOPR /COM, /COM,STIF70 RESULTS: /COM, *VWRITE,LABEL(1,1),LABEL(1,2),VALUE(1,1),VALUE(1,2),VALUE(1,3) (1X,A8,A8,' ',F10.1,' ',F12.1,' ',1F15.3) /COM,---------------------------------------------------------- /OUT FINISH *LIST,vm118,vrt