/COM,ANSYS MEDIA REL. 182 (07/10/2017) REF. VERIF. MANUAL: REL. 182 /VERIFY,VM126 /PREP7 /TITLE, VM126, HEAT TRANSFERRED TO A FLOWING FLUID C*** HEAT, MASS AND MOMENTUM TRANS, ROHSENOW AND CHOI, PAGE 168, EX 7.5 ET,1,FLUID116,1,4,,1 ! THERMAL-FLOW PIPE ELEMENT ET,2,FLUID116,1 R,1,(1/12),.00545415 ! DIAMETER RMORE,,,1.63,.08,.7,.35 ! FLOW DEPENDENT FILM COEFF. MP,KXX,1,.017 ! BTU/hr-ft-F MP,DENS,1,1.4377E-10 ! lbf-hr**2/ft**4 MP,C,1,1.002e8 ! BTU-ft/lbf-hr**2-F MP,VISC,1,1.17418E-10 ! lbf-hr/ft**2 N,1 N,19,,,.46875 ! NODE JUST BEYOND FILL,1,19,8,3,2 ! NODES ALONG PIPE AXIS N,2 N,18 FILL,2,18,7,4,2 ! CONVECTION NODES (ARBITRARY LOCATION) TYPE,1 E,1,3,2,4 EGEN,8,2,1 type,2 E,17,19 ! EXTENSION ELEMENT D,1,TEMP,100 ! INLET AIR TEMPERATURE D,2,TEMP,200,,18,2 ! WALL TEMPERATURE SFE,ALL,,HFLUX,,1.1321e-8 ! FLOW RATE INPUT lbf-hr/ft OUTPR,,LAST ! PRINT FINAL CONVERGED ITERATION OUTPR,NLOAD,1 FINISH /SOLU EQSLV,JCG SOLVE FINISH /POST1 ETABLE,HEAT,NMISC,5 ! STORE HEAT TRANSPORT RATE PRETAB,HEAT ! PRINT HEAT TRANSPORT RATES PER ELEMENT NSEL,S,NODE,,1,19,2 ! SELECT PIPE NODES PRNSOL,TEMP ! PRINT TEMPERATURES ALONG PIPE LENGTH *GET,TO,NODE,17,TEMP ETABLE,HEAT,NMISC,5 ESORT,HEAT *GET,QOUT,SORT,,MAX *GET,QIN,SORT,,MIN *status,parm *DIM,LABEL,CHAR,3,2 *DIM,VALUE,,3,3 LABEL(1,1) = 'To ','Q(in)','Q(out)' LABEL(1,2) = 'F ','BTU/hr','BTU/hr' *VFILL,VALUE(1,1),DATA,123,113.28,139.33 *VFILL,VALUE(1,2),DATA,TO,QIN,QOUT *VFILL,VALUE(1,3),DATA,ABS(TO/123),ABS(QIN/113.28),ABS(QOUT/139.33) /COM /OUT,vm126,vrt /COM,------------------- VM126 RESULTS COMPARISON ------------- /COM, /COM, | TARGET | Mechanical APDL | RATIO /COM, *VWRITE,LABEL(1,1),LABEL(1,2),VALUE(1,1),VALUE(1,2),VALUE(1,3) (1X,A8,A8,' ',F10.2,' ',F12.2,' ',1F15.3) /COM,---------------------------------------------------------- /OUT FINISH *LIST,vm126,vrt