/COM,ANSYS MEDIA REL. 182 (07/10/2017) REF. VERIF. MANUAL: REL. 182 /VERIFY,VM159 /PREP7 /TITLE, VM159, TEMPERATURE CONTROLLED HEATER C*** REFERENCE - SELF-CHECKING (RESPONSE FOLLOWS INPUT REQUEST) ANTYPE,TRANS ET,1,MASS71,,,1 ! THERMAL MASS ET,2,LINK34 ! CONVECTION ELEMENT ET,3,COMBIN37,,,8,,1 ! CONTROL ELEMENT R,1,2.7046E-4 ! THERMAL CAPACITANCE OF HEATER R,2,2.7046E-3 ! THERMAL CAPACITANCE OF BOX R,3,8.1812E-3 ! SURFACE AREA OF HEATER R,4,4.1666E-2 ! SURFACE AREA OF BOX R,5,,,,100,125,-10 ! CONTROL TEMPERATURES, HEAT FLOW RMORE,,1 ! INITIAL CONTROL STATUS (ON) MP,HF,1,4 N,1 *REPEAT,4,1 E,1 ! HEATER TYPE,2 REAL,3 E,1,2 ! CONVECTION LINK TYPE,1 REAL,2 E,2 ! BOX TYPE,3 REAL,5 E,4,1,2 ! CONTROL TYPE,2 REAL,4 E,2,3 ! CONVECTION LINK FINISH /SOLU TIME,.2 IC,1,TEMP,70 ! UNIFORM STARTING TEMPERATURE IC,2,TEMP,70 KBC,1 D,3,TEMP,70 D,4,TEMP,0 AUTOTS,ON OUTPR,,10 OUTRES,,ALL TINTP,,,,0.5,0.5,0.2 DELTIM,0.10000E-02,0.10000E-02,0.20000 /OUT,SCRATCH SOLVE FINISH /POST26 NSOL,2,1,TEMP NSOL,3,2,TEMP ESOL,4,4,,NMISC,1,STAT /OUT, PRVAR,2,3,4 /GRID,1 ! DISPLAY BOX TEMP VS. TIME /AXLAB,Y,TEMP PLVAR,3 /GRID,0 ! DISPLAY STATUS VS. TIME /AXLAB,Y,STAT PLVAR,4 FINISH /OUT,vm159,vrt /COM,----------------------------------------------------------- /COM,NOTE: THERE ARE VERIFIED RESULTS IN VM159 NOT CONTAINED IN /COM,THIS TABLE /COM,----------------------------------------------------------- /OUT FINISH *LIST,vm159,vrt