VM272

VM272
2-D and 3-D Frictional Hertz Contact

Overview

Reference:Two Dimensional Mortar Contact Methods for Large Deformation Frictional Sliding, International Journal for Numerical Methods in Engineering Vol.62, pp 1183-1225.
Analysis Type(s):Static Analysis (ANTYPE = 0)
Element Type(s):
2-D 4-Node Structural Solid (PLANE182)
2-D 2-Node Surface-to-Surface Contact (CONTA171)
2-D Target Segment (TARGE169)
2-D Structural Surface Effect (SURF153)
3-D 8-Node Structural Solid (SOLID185)
3-D 4-Node Surface-to-Surface Contact (CONTA173)
3-D Target Segment (TARGE170)
3-D Structural Surface Effect (SURF154)
Input Listing:vm272.dat

Test Case

Two parallel linear elastic half cylinders of radius R are pressed by a small distributed pressure p. A tangential pressure, q, is then applied to cause friction at the contact interface. The bottom of the lower cylinder is fixed in all directions. Determine the contact pressure and friction results across the contact interface.

Figure 272.1:  Hertzian Contact Problem Sketch

Hertzian Contact Problem Sketch

Material PropertiesGeometric Properties Loading

E=200.0 N/mm2

v=0.3

R = 8.0 mm

p=0.625 N/mm

q= 0.05851 N/mm

Analysis Assumptions and Modeling Notes

This problem is solved in two ways:

In the first analysis, the cylinders are modeled and meshed with plane elements with plane strain behavior. The problem is solved using 2-D surface to surface contact elements with surface-projection definition (KEYOPT(4)=3) and updating contact stiffness based on stresses of underlying elements (KEYOPT(10)=2). In the second analysis, the cylinders are modeled with 3-D solid elements with unit thickness in the Z direction. The same element options and contact damping used in 2-D analysis are applied to 3-D analysis. The simulations use two load steps; the first is a ramped normal pressure of 10 N, applied on the top surface of the upper cylinder, and the second is a ramped tangential pressure of 0.93622 N, also applied to the top surface of the upper cylinder.

Figure 272.2:  Load History Diagram

Load History Diagram

Analytic results approach zero more rapidly than computed results toward the end of the contact interface. These small differences are due to mesh discretization and are considered acceptable.

The plots below show contact pressure and friction with respect to distance along X from the center for both cases.

Figure 272.3:  Plot of Contact Results for 2-D and 3-D Models

Plot of Contact Results for 2-D and 3-D Models

Results Comparison

Table 272.1:  Contact Pressure 2-D

Location (mm) Target Mechanical APDL Ratio
0.0009.3514 9.35771.001
0.1009.2494 9.25661.001
0.2018.9366 8.94831.001
0.3018.3896 8.41211.003
0.4017.5581 7.60371.006
0.5016.33176.43071.016
0.6014.39244.64311.057

Table 272.2:  Contact Friction 2-D

Location (mm) Target Mechanical APDL Ratio
0.000 0.5063 0.52801.043
0.100 0.5140 0.53011.031
0.201 0.5395 0.58561.085
0.301 0.5926 0.66911.129
0.401 0.7069 0.78771.114
0.501 1.2663 1.20920.955
0.6010.87850.92861.057

Table 272.3:  Contact Pressure 3-D

Location (mm) Target Mechanical APDL Ratio
0.0009.3514 9.44351.010
0.100 9.2494 9.34771.011
0.201 8.9366 9.03501.011
0.301 8.3896 8.49051.012
0.401 7.55817.66851.015
0.501 6.3317 6.45031.019
0.6014.39244.51071.027

Table 272.4:  Contact Friction 3-D

Location (mm) Target Mechanical APDL Ratio
0.000 0.50630.52761.042
0.100 0.51400.54281.056
0.201 0.53950.53450.991
0.301 0.59260.63261.068
0.401 0.70690.75521.068
0.501 1.26631.29041.019
0.601 0.87850.90211.027


Release 18.2 - © ANSYS, Inc. All rights reserved.